No Pressure from Gun/Wand

Is faucet open?

Open faucet

Inadequate water supply? (4gpm @ 20 psi)

Improve water supply.

Wand nozzle warn or damaged?

Replace nozzle.

Air in pump?

Turn off engine, depress trigger on gun
until steady stream of water is released.

Water inlet screen clogged?

Clean inlet screen.

Unit stored in freezing temperatures?

Thaw unit completely, including hose, gun
and wand.

If pressure is still not restored, take the
power washer to a authorized KDAR ser-
vice center.

YES

YES

YES

YES

YES

YES

NO

NO

NO

NO

NO

NO

No Intake of Chemicals

Is injection tube securely attached to unit?

Is the injection tube cracked or split?

Is the correct nozzle attached to the wand?

Is the injection tube strainer clogged or
blocked?

If injection is still not restored, take the
power washer to a authorized KDAR ser-
vice center.

Attach tube securely to unit.

Replace injection tube.

Attach correct nozzle.

Clean the strainer.

YES

YES

YES

YES

NO

NO

NO

NO