Kestrel® 2000 Pocket Weather® Meter

3

OPERATION

1. Slide off cover.
2. Turn on. Press the center button (

) to turn on the unit.

3. Select operating mode. Press the right arrow (

) to scroll through the measurements

listed below. Press the left arrow (

) to scroll through the measurements in reverse

order. The instantaneous measurements will be displayed. (See Understanding the

Measurements section for more information.)

4. Select the units of measure. Press

while holding

to scroll through the units

of measure.

Mode

Hint

Icon

Units of Measure

Wind Speed

SPd

m/s, ft/min, km/h, mph,
kt, B

Max Gust

SPd

MAX

m/s, ft/min, km/h, mph,
kt, B

Avg Speed

SPd

AVG

m/s, ft/min, km/h, mph,
kt, B

Temperature

dEG

C, F

Wind Chill

chill

C, F

5. Hold mode. Press

while holding

to hold the measured value on the display. The

word “HOLD” will blink to indicate the Hold Mode. Press

while holding

to exit

the Hold Mode. This mode can be useful for taking measurements when unable to view

the display, as within a duct. The Max and Avg Wind Speed Modes will continue to work

as usual.

6. Turn on the backlight. Press

to activate the backlight for 10 seconds. If

or

are

pressed while the backlight is illuminated, the backlight will remain illuminated

for another 10 seconds. Press

while the backlight is illuminated to manually turn off

the backlight.
7. Turn off. Hold

for 2 seconds to manually turn off the unit. The unit will automatically

turn off if no buttons have been pressed for 45 minutes.

UNDERSTANDING THE MEASUREMENTS

Wind Speed - Average over the previous three seconds. The measurement will be accurate
for air flow through the front or rear of the unit.
Maximum Wind Gust - Maximum 3-second wind speed since the unit was turned on.
Average Wind Speed - average wind speed since the unit was turned on.