Cmor dome, 10 alarms – Videoswitch CMOR D2 Dome User Manual
Page 34

CMOR Dome
Videoswitch Page
31
Vc601i.doc
5
Move joystick/arrow key right
Cross lines appear on screen
6
Move camera to required view
7
Select OK (Vi K/B) or 01+preset (Pelco K/B), or Preset, 10
,1 (on DS2) or wait 15 seconds until a red mask patch
appears
Red mask patch appears
8
Scroll to next MASK number (using arrow keys or joystick
UP/DOWN)
Blue mask patch appears
9
Move joystick or arrow key to the RIGHT
Cross lines appear
10
For each new mask position, repeat steps 4 to 7
12
When all mask positions have been created , exit menus
& save by moving joystick left TWICE
‘Saving config…’ (appears on
bottom left of screen)
5.10 Alarms
If the alarm option is installed in the power supply, the dome will go to presets when an
alarm occurs. Alarms 1 to 16 map to presets 1 to 16 respectively.
Note that if the alarms are connected directly to the digital recorder (DVR) rather than the
alarm option, the following settings have no effect.
5.10.1 New alarm dwell
When a new alarm occurs, the dome will go to the corresponding preset.
If multiple alarms occur, the presets will be called up in sequence. However, the dome will
wait at each preset position for the dwell time set by this option (in seconds).
5.10.2 Alarm cycle time
If alarms still exist after all alarm presets have been visited for the New alarm dwell time, the
presets of the still active alarms will now be toured using the cycle time (in seconds)
specified in this option.