Command examples, RS-232 source sends:
$s99sbyoff
> All units enter standby
$s04comon
> Turn on RS-232 communications for zone 4
$s05comoff
> Turn off RS-232 communications for unit 2, zone 1
$s99comen
> Turn on RS-232 communications for every zone on every unit
$s09comdis
> Turn off RS-232 communications for every zone on unit 3
$s02src2
> Sets zone 2 (unit 1 zone 2) to source 2
$s10src3
> Sets zone 10 (unit 3 zone 2) to source 3
$s08vo+
> Increments volume on zone 8 (unit 2 zone 4)
$s03vo-
> Decrements volume on zone 3 (unit 1 zone 3)
$s14vol012
> Sets absolute volume level of zone 14 (unit 4 zone 2) to level 12
$s99muten
> Mutes every zone on every unit
When MULTIzone is powered on, the previous status of the unit will be restored. If a particular zone of the unit was previously in
RS-232 mode the particular settings for that zone will be restored, e.g. the source input, volume level, or mute. Alternatively, if a
particular zone was in manual panel mode the front controls will become active.
Before a zone can be brought under RS-232 control it must first be switched from manual panel mode to RS232 by using the
“comon” for a particular zone, or the “comen” system wide or unit command (all described above).
Note: the front panel controls will be disabled when the unit is in RS-232 mode. Make sure the required unit zones are brought
out of RS232 by sending the appropriate “comoff” or “comdis” commands.
Where
can be
MULTIzone command response
Range of
Notes
vol
Sets absolute volume level of zone
000 to
027
000=MIN, 027=MAX
vo+
Increments volume level of zone
N/A
Will not increment above 027
vo-
Decrements volume level of zone
N/A
Will not decrement below 000
muton
Zone enters mute
N/A
Previous volume level recorded
mutoff
Zone de-mutes
N/A
Previous volume level restored
comon
Zone enters RS-232 control
N/A
Manual panel controls disabled – RS232 settings asserted
comoff
Zone exits RS-232 control
N/A
RS-232 mode disabled – manual panel settings asserted
src
Selects input source (1 through 6) as zone output
1 to 6
Selects source 1 through 6