19. [LOD1]
This command enables the loudness feature.
Command Format: [LOD1CnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Turn ON the Loudness feature of the 
MT109-102 in slot #4 by sending the command 
[LOD1C4].
20. [CLR]
This command clears the card and resets it to 
its factory defaults. All volume levels are set to 
maximum, bass and treble are set to midrange, 
loudness is turned off and mute is turned off.
Command Format: [CLRCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Clear the MT109-102 in slot #4 by sending the 
command [CLRC4]. Send the status command 
after the clear command and receive the 
following feedback:
In1Vol=16/16 
In2Vol=16/16 
In3Vol=16/16 
OutVol=16/16 
Bass =08/16 
Treble=08/16 
Loudness:OFF
VOLUME RAMPING FEATURE
The following 7 commands are used to control the 
output volume of the MT109-102. They may be 
used with computer control, but also are designed 
to be used with the {SETVK} command using keys 
on the Front Panel. The following code sample 
sets front panel keys 8 and 10 to Ramp Up and 
Ramp Down respectively. See your Front Panel 
User’s Guide for more details.
When defined as a volume control key, the key will 
respond to two conditions: press and release. 
Below, subroutine 8 starts ramping up when key 8 
is pressed and subroutine 10 starts ramping down 
when key 10 is pressed. Subroutine 108 stops 
ramping when either key is released. 
{WRS8=RUPC4}
//Ramp Up
{WRK8=8,108,0,0,0}
//Press= start, release= stop
{WRS10=RDNC4}
//Ramp Down
{WRK10=10,108,0,0,0} //Press= start, release= stop
{WRS108=RSTC4}
//STOP RAMPING
{SETVK8}
//Set key 8 as volume key
{WRLK8=VOL_UP}
//Define Key 8 Label
{SETVK10}
//Set key 8 as volume key
{WRLK10=VOL_DN}
//Define Key 8 Label
[RAMP=10C4]
//Set the ramp rate.
21. [RUP]
This command ramps the OUTPUT volume to 
its maximum level at the rate defined using the 
[RAMP] command.
Command Format: [RUPCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume from a starting level of 
10 to the maximum level of 16 for the card in 
slot #8. Send the command [RUPC8] and the 
system will respond with the following feedback:
[11][12][13]…[16]
22. [RUP=xx]
This command ramps the OUTPUT volume to a 
user defined level at a rate defined using the 
[RAMP] command.
Command Format: [RUP=xxCnUi]
xx = Stop Level (xx = # from 01-16)
Cn = Card ID (n = # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)