Haws 5010.6427SS User Manual
Page 2

01/09
Model 5010.6427SS
Page 2 of 4
 
 
NOTE: To remove head when used with electric water cooler, keep the inlet nipple from turning 
by holding it with locking pliers inside the fountain, beneath the basin. 
 
 
Step 1: Gain access to flow adjustment screw by removing cover nut and button (see 
Installation Drawing).
 
Step 2: Adjust flow with screwdriver: clockwise for more flow, counterclockwise for less. 
 
Step 3: If desired flow is not obtained, clean screen located at base of valve body and make 
 
 sure screwdriver stop is fully opened. 
 
Step 4: Replace button and cover nut. 
 
 
Note: Replacement cartridge, screen, and gasket are available as P/N VRK5010. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© 2009 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used
in these materials are the exclusive property of Haws Corporation.
