Troubleshooting – Haws 1900 User Manual
Page 4
02/14
Model 1900
Page 4 of 7
height (see
“Mounting Frame Detail” in installation drawing to install at 48” reach
height), assuring the mounting frame is installed level.
Rear drain only:
Cut the opening in the wall for the drain, using the bottom of the mounting
frame as a reference point for the bottom of the cutout. Take care not to cut
below the bottom of the mounting frame, as this may be visible after
final installation. The cutout should be as wide as the bottom opening in the
mounting frame, and 2-
1/2” high (see “Mounting Frame Detail” in installation
drawing).
Run the supply tubing either up the back of the bottle filler or up through the wall.
Connect the tubing to the push-in elbow in the bottle filler.
Mount the bottle filler to its frame with the supplied #8 x 1/2" flat head screws (qty. 4).
Rear drain only:
Connect the drain plumbing.
Step 5:
Testing:
Turn on the water supply. Press the push button to dispense water; check for leaks.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. Insufficient water flow.
1a. Check that any inlet screwdriver stop valve
(not supplied) is wide open. Turn
counterclockwise.
b. Verify minimum 30 psi flowing supply
pressure.
c. Clean strainer. See 5874SS Valve Manual.
d.
e.
Adjust valve to increase flow. Use front
adjust screw or see 5874SS Valve Manual.
Make sure nozzle is free of debris.
2. Excessive water flow.
2a. Adjust valve to decrease flow. Use front
adjust screw or see 5874SS Valve Manual.
3. Water flow is crooked or
splatters.
3a.
b.
c.
Make sure nozzle is free of debris.
Verify that bottle filler is installed level and
straight.
Adjust valve to decrease flow. Use front
adjust screw or see 5874SS Valve Manual.
4. Drain overflows.
4a. Check drain basin for obstructions.
For more information about Haws products, see our website
© 2014 Haws
®
Corporation
– All Rights Reserved
HAWS
®