Haws 1152 User Manual
Page 2
04/14
Model 1152
Page 2 of 4
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open end
wrench.
LOCATION OF UNIT: When installing Model 1152 Drinking Fountain, local, state or federal
codes should be adhered to. If height other than shown is required, then dimensions must be
adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2” IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.
PLUMBING CONNECTIONS: Inlet is 1/4” female IPS. Waste outlet is female 1-1/4” IPS.
MAINTENANCE: Periodically clean the strainer.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1. Insufficient bubbler flow.
1a.
Check that inlet screwdriver stop valve
(not supplied) is wide open. Turn
counterclockwise.
b.
Verify minimum 30 psi flowing supply
pressure.
© 2014 Haws
®