Haws 1119FR User Manual
Page 2
![background image](/manuals/408058/2/background.png)
04/10
Model 1119FR
Page 2 of 4
RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open
end wrench.
LOCATION OF UNIT: The Model 1119FR Drinking Fountain is a wheelchair accessible
drinking water facility. The height dimensions that are shown meet current ADA
requirements. When installing this unit, local, state or federal codes should be adhered to. If
height other than shown is required, then dimensions must be adjusted accordingly.
SUPPLY LINE: The minimum recommended line size is 1/2” NPT with 30-90 psi (2-6 ATM)
pressure. Where sediment or mineral content is a problem, an inlet filter is recommended.
PLUMBING CONNECTIONS: Waste outlet is 1-1/4” IPS (located on 6521FR Valve box).
MAINTENANCE: Refer to 6521FR operation and maintenance sheet for more information.
TROUBLESHOOTING
PROBLEM
REPAIR CHECKLIST
1.
Insufficient bubbler flow.
1a. Check that inlet screwdriver stop valve
is wide open. Turn counter-clockwise.
b. Verify minimum 30 psi flowing supply
pressure.
c. Adjust valve to increase flow. See
6521FR Valve Manual.
General Notes:
Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out to ensure
correct engagement with O-Ring.
For more information about Haws products, see our website:
www.hawsco.com
© 2010 Haws
®
Corporation – All Rights Reserved
HAWS
®
and other trademarks used
in these materials are the exclusive property of Haws Corporation.