beautypg.com

Haws 1109FR User Manual

Page 2

background image

04/10

Model 1109FR/1109FRBP

Page 2 of 4

RECOMMENDED TOOLS: Hack saw, pipe joint sealant, screwdriver, level, 12" adjustable
wrench, 10" pipe wrench, 5/64“ hex key wrench, 9/16”, 1/2", 7/16” socket wrench or open
end wrench.

LOCATION OF UNIT: The Model 1109FR/1109FRBP Drinking Fountain is a wheelchair
accessible drinking water facility. The height dimensions shown, meet current ADA
requirements. When installing this unit, local, state or federal codes should be adhered to.
If height other than shown is required, then dimensions must be adjusted accordingly.

SUPPLY LINE: The minimum recommended line size is 1/2“IPS with 30-90 psi (2-6 ATM)
flowing pressure. Where sediment or mineral content is a problem, an inlet filter is
recommended.

PLUMBING CONNECTIONS: Waste outlet is 1-1/4” IPS (located on 6521FR Valve box).

MAINTENANCE: Periodically clean the strainer. Refer to 6521FR Valve Operation and
Maintenance Sheet for more information.

TROUBLESHOOTING

PROBLEM

REPAIR CHECKLIST

1.

Insufficient bubbler flow.

1a. Check that inlet screwdriver stop valve

is wide open. (Customer supplied).
Turn counterclockwise.

b. Verify minimum 30psi flowing supply

pressure.

c. Adjust valve to increase flow. Use

front adjust screw see 6521FR Valve
Manual.

General Notes:
Before tightening nut and ferrule assembly, push tubing into fitting until it bottoms out
to ensure correct engagement with O-Ring.





For more information about Haws products, see our website:

www.hawsco.com