led status

proBleM

solutIon

7

8

9

Self diagnostic check has detected

a problem with the gas valve driver

circuit, internal microprocessor, or

other internal circuits.

1 Turn the power off for 10-20 seconds then on again to

clear these error codes.

2 If any of these error codes persist or cannot be cleared -

replace the gas control valve/thermostat.

10

Flame signal sensed out of proper

sequence.

1 Turn the power off for 10-20 seconds then on again to

clear these error codes.

2 Replace the gas control valve/thermostat if this error code

persists.

11

Water in the tank has exceeded the

maximum allowable temperature,

activating the ECO (energy cut off).

1 Turn the power off for 10-20 seconds then on again to

clear these error codes.

2 Replace the gas control valve/thermostat if the error code

persists.

12

One or both of the temperature

adjust buttons are stuck.

1 Press and release both temperature adjust buttons

several times - cycle water heater power off and on.

2 Replace the gas control valve/thermostat if the error code

persists.

13

The water temperature sensor

(located in the control valve's

immersion probe) is either open or

shorted.

1 Turn the power off for 10-20 seconds then on again to

clear these error codes.

2 Replace the gas control valve/thermostat if the error code

persists.

14

The FV (fl ammable vapor) sensor

is either open or shorted.

1 Turn off power to the water heater. Ensure all FV sensor

wiring, the ignitor assembly plug, and the ignitor assembly

socket on the bottom of the Intelli-Vent control are making

good contact. Repair or replace any worn/damaged

components that are not making good connection..

2 Replace the FV sensor.

15

Self diagnostic check has detected

the presence of fl ammable vapors

from the FV (fl ammable vapor)

sensor.

1 Do not touch any electrical switch, do not use any phone

in your building, and do not try to light any appliance.

2 Smell around the water heater to ensure there are no gas

leaks at the gas control valve/thermostat, in the supply

gas line(s), or any other type of fl ammable vapor(s) in the

area.

3 Carefully inspect the area surrounding the water heater

for any substances such as gasoline, paint, paint

thinners, varnish, or cleaners that could emit flammable

vapors. Remove anything that can potentially emit

flammable vapors from the area and store it properly in a

different location.

4 Call the technical information support phone number

shown on the water heater labeling for further assistance.

16

Air pressure switch circuit is

opening repeatedly during one

heating cycle.

LDO (Lint, Dust, and Oil) lockout

condition.

1 On models equipped with a dilution air intake screen on

the blower assembly - check/clean the screen.

2 On models equipped with a combustion air intake screen

on the base ring (bottom) of the water heater - check/

clean the screen.

3 Ensure intake air screen(s) on models so equipped are

not obstructed.