5 packaging and transportation, Section 5 - testing, 1 general – ACR Electronics Mini B300 2766.6 User Manual
Page 12: 2 operational testing

8
Y1-03-0167 Rev. B
1. To ensure continued reliability, the unit should be checked for operation at least once every 90
(ninety) days, following the procedure of Section 5.2.
2. Do not use cleaners or petroleum distillates.
 
 
4.5 
PACKAGING AND TRANSPORTATION 
 
The MINI B
300
TM
ILS contains lithium batteries (solid cathode, total 3.4 grams lithium). The
original shipping carton may be used or consult your local transportation authority with regard to 
applicable regulations for transporting the EPIRB. 
 
 
SECTION 5 - TESTING 
 
5.1 
GENERAL 
 
The following paragraphs detail the Beacon testing procedures. 
Note - Read the entire test procedure before testing. 
5.2
OPERATIONAL TESTING 
 
1. The Beacon can be tested by turning it "ON". Warning - Do not hold beacon near face or 
body while releasing the antenna. Antenna is spring loaded and deploys rapidly.
2. Red LED indicator will illuminate continuously for 5 (five) seconds, indicating a functional
battery. After the 5 (five) seconds, the LED will blink, confirming RF signal transmission, and 
an audible warble will sound, confirming RF signal transmission. 
 
NOTE: Tests of more than 5 (five) second duration must be conducted at designated times and 
duration unless special arrangements are made with the USCG, FCC and/or local FAA authorities. 
Operational transmission testing may be executed only during the first five (5) minute period of 
any hour and only for three tone sweeps or one operational transmission (LED light 
flashing/audio warble) second, of the audio modulating whichever is longer. 
 
The MINI B
300
TM
ILS has a speaker, fed by voltage from the microprocessor and the transmitter,
which produces the audible warble. This EPIRB will emit a distinctive warbling sound when 
operationally tested. Any change in the audible warble, (a loss of sound or intermittent sound), is 
an indication that you should have your beacon serviced at an authorized service station. Conduct 
this test only during the first five- (5) minutes of each hour as indicated above. 
 
 
 
 
 
You can verify that your EPIRB is actually transmitting by turning it "ON" near a FM radio tuned 
to 99.5 MHz. The radio will receive the signal and will broadcast the familiar “warble” through its 
speakers if the EPIRB is transmitting properly. Conduct this test only during the first five (5) 
minutes of each hour as indicated above. 