Description of models, Codes for ordering pvc calibration cylinders: cc – Griffco Valve CC PVC User Manual
Page 2

Description of models:
Sealed:
Top is glued to cylinder and contains a
vent or overflow connection. (FNPT).
Used in applications where there is a
positive suction head and a permanent
installation is desired.
Loose Cap: (Avail. up to 20,000 mL)
Top is loose and does not have a
connection in the top. Dust cover only.
Used in applications where there is no
positive suction head and the cylinder
must be filled from the top.
EZ-Clean: (Avail. 100 – 7000 mL
only)
Top is sealed with an O-ring and has a
vent connection, but removable for
easy cleaning. Used in applications
where frequent cleaning is required
such as polymer, alum, ferric chloride
or chlorine.
Codes for Ordering PVC Calibration Cylinders:
CC
□□□□ □ □
□
1
2 3 4
1 = Size
2 = Top End Cap Style
3 = Connections
4 = Oring Material
(Top Cap Only)
(Union & EZ end cap orings)
0100 – 100 mL
Blank – Sealed
Blank – Threaded
Blank – FKM (Viton
®
)
0200 – 200 mL
L – Loose
(up to 20000mL)
S – Socket
E - EPDM
0300 – 300 mL
EZ – EZ Clean
(up to 7000mL)
F – Flanged
0500 – 500 mL
U – Union
(PTFE Encapsulated
1000 – 1000 mL
or FFKM are available
2000 – 2000 mL
upon request)
3000 – 3000 mL
4000 – 4000 mL
5000 – 5000 mL
7000 – 7000 mL
10000 – 10000 mL
15000 – 15000 mL
20000 – 20000 mL
30000 – 30000 mL
40000 – 40000 mL
Website:
www.griffcovalve.com
email:
Capacity
(mL)
◊
Max Flow
▲
(USgph) (lph)
Scale
(mL)
Scale
▲
(gph)
A
(in)
B
(in)
C
(in)
100
3.17 12 1 .1 11 1.5 1/2
200
6.34 24 1 .1 19 1.5 1/2
300
9.51 36 5 .2 13 2.2 1/2
500
15.85 60 5 .2 13 2.5 3/4
1,000
31.70 120 5 .2 22 2.5 3/4
2,000
63.40 240 10 1 20 3.7 1
3,000
95.10 360 10 1 17 4.9 1
1/2
4,000
126.8 480 10 1 37 3.7 1
5,000
158.5 600 10 1 28 4.9 1
1/2
7,000
221.9 840 10 1 38 4.9 1
1/2
10,000
317.0 1200 100 5 25 6.95 2
15,000
475.5 1800 100 5 36 6.95 2
20,000
634.0 2400 100 5 47 6.95 2
30,000
952.0 3600 200 10 65* 9.5* 4
40,000
1,268.0 4800 200 10 77.5* 9.5* 4
Top End
Cap
Clear PVC
Cylinder
Bottom
End Cap
▲ Max Flow and gph scale are based on 30 second drawdown * Reference only
◊ For 60 sec draw down, double capacity in mL or flow size