Yetter Systems One Seed Jet II Closed Center Hydraulic System User Manual
Page 10

10
 
Problem
Blower speed is uneven. 
 
 
 
 
 
 
Hydraulic oil is too hot. 
 
 
 
 
 
 
 
 
 
Hydraulic control lever in tractor 
not holding detent position. 
 
 
 
 
No seed being transferred. 
 
 
 
Airlock will not turn. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Cause
Operating with open center 
hydraulic system. 
Tractor oil filters are plugging. 
Low hydraulic fluid level in 
tractor. 
Faulty flow control valve. 
 
Insufficient oil cooling. 
Plugged cooling radiator. 
Cooling radiator is too small. 
No cooling radiator. 
Oil reservoir is too small. 
Oil bypass rate is very high. 
 
Low hydraulic fluid level in the 
tractor. 
 
Hydraulic line pressure exceeds 
the detent setting. 
Pressure spikes in the hydraulic 
system. 
Faulty detent mechanism. 
 
Seed gate closed. 
Tractor oil cold. 
Seed hose plugged. 
 
Low power to electric motor. 
 
 
 
Airlock vane blocked. 
 
Faulty electric motor. 
 
Module switch open. 
 
Poor or damaged wiring. 
 
 
 
Blown fuse. 
 
Module switch out of adjustment. 
 
 
 
Faulty remote switch. 
 
Failed module. 
 
 
 
 
Solution
Recommend closed center or 
load sensing system. 
Service tractor hydraulic filters. 
Maintain adequate oil levels. 
 
Service tractor hydraulic system. 
 
Review fan drive requirements. 
Clear radiator cooling fins. 
Increase cooling capacity. 
Add cooling capacity. 
Increase reservoir size. 
Reduce bypass rate. Increase 
fan speed. 
Maintain adequate oil levels. 
 
 
Hold the lever to maintain 
operating position. 
Operate selector and spool 
valves gently. 
Service as required. 
 
Open gate. 
Run tractor to warn oil. 
Disconnect hose and clear. 
 
Check wiring connections. 
 
Check battery voltage. 
 
Remove blockage. Example: wet 
seed. 
Test/Replace electric motor. 
 
Blower not running. 
 
Inspect and repair motor module 
and switch wiring and 
connections. 
 
Module fuses. 
 
Adjust so switch is open when 
blower not running. Closed when 
blower is running. 
 
Replace remote switch. 
 
Replace relay or module. 
 
 
 