12.0 Diagnosis of faults and repair

EN

Fault Cause Repair

The motor fails to start

Oil supply not connected

Connect the oil hose

Oil supply closed

Open the valve

No oil pressure

Start the hydraulic pump

The pump is frozen

Let the pump thaw

Working pressure too high Nozzle partly blocked

Clean the nozzle

Working pressure too low

Valve for regulation of water

Open fully the valve for regulation

capacity is not adjusted to max. of water. Turn in the direction

pressure

indicated by the arrow

Regulating valve open

Close the regulating valve

Irregular working pressure Air in the pump

Repeat the venting procedure

During self-priming

Suction height too high or water Read the paragraph conc. self-

too hot

priming p. 6

Filter blocked

Clean the fi lter. See p. 11

During direct water

Insuffi cient water supply from

Change to a water supply with

connection

the water works

greater output. If this is not

possible; turn the valve for regulation of

the water capacity in the opposite

direction of that indicated by the

arrow, until the machine works smooth ly.

No working pressure

Nozzle blocked

Clean the nozzle

No water

Check the water connection

High pressure hose/lance frozen Allow the high pressure hose/lance

to

thaw

By-pass valve frozen

Allow the machine to thaw

Should faults occur other than those mentioned above, please contact the nearest Nilfi sk-ALTO service
or gan i za tion.