beautypg.com

Quick start guide: symnet radius aec, Declaration of conformity, Configuring ip parameters – Symetrix Radius AEC User Manual

Page 3: Arc pinout, Locating hardware, Ip configuration with composer, Ip configuration with the front panel

background image

Declaration of Conformity

QUICK START GUIDE:

SymNet RADIUS AEC

3

1

!

Warning! Refer to the RJ45 Warning for compatibility

information.
The Symetrix ARC-PSe provides serial control and power
distribution over standard CAT5/6 cable for systems with
more than 4 ARCs, or, when any number of ARCs are
located long distances from a Integrator Series, Jupiter or
SymNet DSP unit

.

Declaration of Conformity

We,

Symetrix Incorporated, 6408 216th St. SW,

Mountlake Terrace, Washington, USA, declare under our

sole responsibility that the product:

SymNet RADIUS AEC

to which this declaration relates, is in conformity with the

following standards:

IEC 60065, EN 55103-1, EN 55103-2,

FCC Part 15, RoHS

The technical construction file is maintained at:

Symetrix, Inc.

6408 216th St. SW

Mountlake Terrace, WA, 98043 USA

The authorized representative located within the European

Community is:

World Marketing Associates

P.O. Box 100

St. Austell, Cornwall, PL26 6YU, U.K.

Date of issue: March 14, 2013

Place of issue: Mountlake Terrace, Washington, USA

Authorized signature:

Paul Roberts, CEO, Symetrix Incorporated.

Configuring IP Parameters

Locating Hardware

Discovery of, and connection to, RADIUS AEC
hardware is done with the Locate Hardware
dialog found under the Hardware menu or by
clicking the Locate Hardware icon in the tool
bar or on a particular RADIUS AEC unit itself.

IP Configuration with Composer

The Locate Hardware dialog will scan the
network and list available units. Select the

RADIUS AEC unit you wish to assign an IP address to and
click the Properties button. If you wish to assign RADIUS
AEC a static IP address, select “Use the following IP
address” and enter the appropriate IP Address, Subnet
mask and Gateway. Click OK when finished. Now, back in
the locate hardware dialog, ensure the RADIUS AEC device
is selected and click “Select Hardware Unit” to use this
RADIUS AEC hardware in your Site File. Close the Locate
Hardware dialog.

IP Configuration with the Front Panel

RADIUS AEC IP information can also be edited from the
front panel. RADIUS AEC’s front panel interface starts up
in System Mode out of the box. Press LEFT or RIGHT until
you get to the DHCP menu. If DHCP is enabled, press
ENTER and then UP or DOWN until it reads DISABLED,
then press ENTER to confirm. Now press RIGHT until you
get to the IP Address menu. Press ENTER to edit using the
UP, DOWN, LEFT and RIGHT buttons to change digits and
navigate between digits. Press ENTER again when finished
editing. Repeat as necessary for Subnet Mask and Gateway
Address.
Note: If the IP Address is changed from the front panel,
Composer Design unit(s) must be updated to match by right
clicking on the units and choosing Unit Properties or by
Locating Hardware as detailed previously.

The RJ45 connectors labeled “ARC” are only for use

with the ARC series of remotes. DO NOT plug the ARC

connectors on Symetrix products into any other RJ45

connector. The “ARC” RJ45 connectors on Symetrix

products can carry up to 24 VDC / 0.75 A (class 2 wiring)

which can damage Ethernet circuitry.

ARC Pinout

The RJ45 jack distributes power and RS-485 data to one
or more ARC devices. Uses standard straight-through UTP
CAT5/6 cabling.

1
2
3
4
5
6
7
8

1
2
3
4
5
6
7
8

1 • AUDIO (+)
2 • AUDIO (-)
3 • COMMON GROUND
4 • RS-485 DATA (A)
5 • RS-485 DATA (B)
6 • COMMON GROUND
7 • POWER (+V)
8 • POWER (+V)

Note:

The ARC Audio line may be grounded at the

Symetrix rack-mount device and the ARC wall panel
to provide additional distance.

ARC PORT PINOUT

8

7

6

5

4

3

2

1

Pair 1

Pair 3

Pair 4

Pair 2

- or -

- or -