PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Alarm is on.

(continued)

Display shows . Device

demands more than the

inverter’s continuous

power rating.

Display shows .

Inverter is too hot.

Cycle the inverter power OFF

and ON. If problem persists,

use a larger inverter or a

smaller device.

Increase the ventilation to the

inverter. Move the inverter to a

cooler area. Reduce the power

consumption of the device. The

inverter will automatically reset

after cooling.

Inverter does not

turn on.

Poor contact at terminals

Fuse is blown.

Check for poor connection to

battery or power supply. Make

sure connection points are

clean. Rock clamps back and

forth for a better connection.

A blown fuse is usually caused

by reverse polarity or a short

circuit within the inverter. To

replace, contact a qualified

service technician who will

diagnose the problem and

replace the fuse(s) with the

appropriate replacement(s).