beautypg.com

Trouble shooting guide, Object lock range of detection, Near far – Rubbermaid 401982 User Manual

Page 4: 1on 2 3, Modes of operation switches, Courtesy manual flush button, Urinal model only, Problem cause solution to problem

background image

1

ON

2 3

1

ON

2

3

1

ON

2

3

1

ON

2

3

1

ON

2

3

1

ON

2

3

1

ON

2 3

-

+

Object Lock

Range of Detection

Distance Adjustment Screw

Near

Far

Modes of

Operation

Switches

Normal

Flushes after

each use

Water

Saver

Flushes after

every other use

Sensor Range Reset Button

Courtesy Manual

Flush Button

(Toilet Model Only)

Sanitary

Flushes before

and after

each use

Stadium

Flushes every

3 minutes with

continuous use

Audio

Tone sounds

when batteries

need to be

replaced

ON

OFF

Allows manual activation

of flush when needed.

Distance

Adjustment

Urinal Model Only

Operates

in Normal

Mode Only

Flushes after

each use

ON

1

Audio

Tone sounds

when batteries

need to be

replaced

ON

OFF

Toilet Model Only

Use Sensor

Adjuster

Tool

Battery LED (Yellow)

Flashing LED = Change Batteries

Object Lock Sensor

User-In-View LED (Green)

Flashes 3 Times = User acknowledged & ready

to operate per mode setting.

SWITCH
NO. 3
DOES
NOT
AFFECT
NO.'S
1 & 2.

Urinal Model Only

TROUBLE SHOOTING GUIDE

PROBLEM

CAUSE

SOLUTION TO PROBLEM

Green L.E.D.(light) flashes 3 times

when there are no users

Green L.E.D.(light) flashes

continuously when Object Lock Sensor is

activated by a user

Orange L.E.D.(light) flashes

Not enough water to fixture or too

much water to fixture

Valve will not operate

Valve does not shut off

Valve does not flush even after Object

Lock Sensor has been adjusted

Front of Object Lock Sensor is covered or Object Lock Sensor

is set too far out,registering the opposite wall or door as a

user

AutoFlush unit is in 7 minute start up mode (when first

activated) or Sensor Range Reset Button has been

depressed

Batteries need replacing

Diaphragm damaged or valve control stop

improperly adjusted

Object Lock Sensor range set to close to AutoFlush,batteries

are dead,or water supply

is turned off

Dirt or debris preventing diaphragm from functioning

properly

Dead batteries

Remove item covering sensor or adjust Object Lock

Sensor activation distance.(See Appendix B.Adjusting

the AutoFlush)

Green L.E.D.(light) will flash only 3 times

acknowledging a user is in view after the 7 minute

start up mode

Replace batteries

Replace diaphragm and/or adjust valve control stop

Adjust Object Lock Sensor—Replace batteries—Turn

water on.

Remove dirt or debris,consult valve manufacturer’s

directions

Replace batteries.