Trouble shooting guide, Object lock range of detection, Near far – Rubbermaid 401982 User Manual
Page 4: 1on 2 3, Modes of operation switches, Courtesy manual flush button, Urinal model only, Problem cause solution to problem
1
ON
2 3
1
ON
2
3
1
ON
2
3
1
ON
2
3
1
ON
2
3
1
ON
2
3
1
ON
2 3
-
+
Object Lock
Range of Detection
Distance Adjustment Screw
Near
Far
Modes of
Operation
Switches
Normal
Flushes after
each use
Water
Saver
Flushes after
every other use
Sensor Range Reset Button
Courtesy Manual
Flush Button
(Toilet Model Only)
Sanitary
Flushes before
and after
each use
Stadium
Flushes every
3 minutes with
continuous use
Audio
Tone sounds
when batteries
need to be
replaced
ON
OFF
Allows manual activation
of flush when needed.
Distance
Adjustment
Urinal Model Only
Operates
in Normal
Mode Only
Flushes after
each use
ON
1
Audio
Tone sounds
when batteries
need to be
replaced
ON
OFF
Toilet Model Only
Use Sensor
Adjuster
Tool
Battery LED (Yellow)
Flashing LED = Change Batteries
Object Lock Sensor
User-In-View LED (Green)
Flashes 3 Times = User acknowledged & ready
to operate per mode setting.
SWITCH
NO. 3
DOES
NOT
AFFECT
NO.'S
1 & 2.
Urinal Model Only
TROUBLE SHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION TO PROBLEM
Green L.E.D.(light) flashes 3 times
when there are no users
Green L.E.D.(light) flashes
continuously when Object Lock Sensor is
activated by a user
Orange L.E.D.(light) flashes
Not enough water to fixture or too
much water to fixture
Valve will not operate
Valve does not shut off
Valve does not flush even after Object
Lock Sensor has been adjusted
Front of Object Lock Sensor is covered or Object Lock Sensor
is set too far out,registering the opposite wall or door as a
user
AutoFlush unit is in 7 minute start up mode (when first
activated) or Sensor Range Reset Button has been
depressed
Batteries need replacing
Diaphragm damaged or valve control stop
improperly adjusted
Object Lock Sensor range set to close to AutoFlush,batteries
are dead,or water supply
is turned off
Dirt or debris preventing diaphragm from functioning
properly
Dead batteries
Remove item covering sensor or adjust Object Lock
Sensor activation distance.(See Appendix B.Adjusting
the AutoFlush)
Green L.E.D.(light) will flash only 3 times
acknowledging a user is in view after the 7 minute
start up mode
Replace batteries
Replace diaphragm and/or adjust valve control stop
Adjust Object Lock Sensor—Replace batteries—Turn
water on.
Remove dirt or debris,consult valve manufacturer’s
directions
Replace batteries.