beautypg.com

Powerwinch Quick Catch Pot Puller User Manual

Page 8

background image

C

APSTAN

P

OWERED

L

IFT

A

SSIST

P

OWERWINCH

6

14. Route one R

ED

wire from the battery to the switch location. Be sure to

allow adequate wiring to make connections, allow the wire to have some
slack when routing. Secure the wires with wire ties.

15. At the switch terminate the new wire with a 5/16 ring terminal and attach to

the second short wire from the switch with a 1/4 -20 screw and nut and shrink
wrap.

16. At the battery terminate the R

ED

wire with a #10 ring terminal. Attach the wire to

the "AUX" post of the circuit breaker.

17. Attach the circuit breaker to the

POSITIVE

(+) terminal of the battery.

Black

Green

Black

*awg

Red *

awg

Ring Terminals

1/4-20 x 1/2
Screw & Nut

Tape or

Heat Shrink

= Mechanical Connection

Red

*awg

Circuit Breaker

Battery

pwcs005

Foot Switch

25A Circuit Breaker

(used w/ Capstan 300)

80A Circuit Breaker

(used w/ Capstan 1000 &

Quick Catch Pot Puller)

To Battery
(+12VDC)

Red

Wire

Ring

Terminal

Red

Wire

Ring

Terminal

To Battery (+12VDC)

* Use 8awg wire for Capstan 300

Use 6awg wire for Capstan 1000
Use 6awg wire for Quick Catch Pot Puller

T

ESTING THE

U

NIT

1.

Ensure that all connections are secure and correct.

2. With no rope on capstan, press down the switch. If the motor runs but the

capstan does not turn, motor wires are reversed. Reverse the red and black
wires at the motor leads.

This manual is related to the following products: