2>. The PC Editor should now load. A welcome screen will appear. This closes after 5 seconds (or click on

it). Select NEW from the FILE menu. A window will open showing several different model names, because

the same software is used for some of our pro audio models. Select DPA amp and click OK.

You will

then be presented with 2 options NEW UNIT and NETWORK SCAN.

If your

has already been installed and set-up and you now wish to view and/or modify some

DPA unit

param-

eters,

do the following:

If your

has not been set-up yet, or if you want to replace the existing set-up,

DPA unit

you can create

named profile (NEW UNIT) within the PC Editor. Here's how:

a new

Select NEW from the FILE menu, then

and click OK. Select NEW UNIT. In the window

DPA amp

that appears,

type a new name for the unit you are creating (this is optional). The GANGING (* more Information follows)

option should generally be left at their default settings (unchecked).

Press OK and a window corresponding to the unit you have just named will open up with the factory default set-up
configuration and the block diagram.

Choose ONLINE from the ACTIONS menu and the PC will scan the serial port to verify that the DPA unit is

correctly connected. The NETWORK SCAN window should show the system status (UNIT CONNECTED or N-
OT

DPA

CONNECTED). Pressing OK will cause all the parameters set in the PC Editor to be downloaded to the

unit.

DPA unit

transfer control data in

An ONLINE icon will appear to show that the

and PC are now ready to

real-

time.

*

The inputs and each pair of outputs be "ganged" (linked together) as stereo pairs, so that changes

Ganging:

are simultaneously applied to both channels. This is achieved via the MODIFY UNIT option in the
ACTIONS menu of the PC Editor. However, if you intend to use the channel delay function for speaker 'time
alignment' then you should NOT gang the channels.

If you do not wish this to happen (i.e. if you do not wish to overwrite the current data in the

), then you

DPA unit

must initiate a new session by closing the current window and then selecting NETWORK SCAN (File >New >DPA
unit

DPA unit

> Network Scan) so that the

uploads to the PC.

Every time an upload is made, all the USER PRESETS stored in the

are transferred to the

DPA unit

correspo-

nding numbered presets within the PC Editor.

Select NETWORK SCAN. The program will scan your PC's serial ports. When Done, it will present a list of IDs.

The ID number of the

is 1 (this cannot be changed). The ID list will show if the

(ID 1) is correctly

DPA unit

DPA unit

connected or not. Pressing OK will prompt the system to retrieve (upload) all the parameters and all previously

saved USER PRESETS from the

to your computer. A window will automatically open on your computer

DPA unit

screen. You can now view the settings and edit them (depending on the Lock mode).

Every time a download is made to the

, the user presets in the internal memory (and any unsaved set-

DPA unit

up you were working on) are overwritten. Selecting OFFLINE from the ACTIONS menu will cause the PC to be

disconnected from the

. Be aware that immediately selecting ONLINE again will

DPA unit

prompt the PC Editor

to perform a new scan of the network and automatically download the settings from the PC to the

.

DPA unit

9

5.4 Edit Mode (Password Protection)

Full Edit:

This is the DEFAULT mode. No password is set at the factory. From here you can lock the unit by clicking the

Lock buttons. A text box will open, allowing you to enter a password of your own

Total

choice. Click OK. impor-

tant that you remember this password.

Total Lock:

No editing is possible in this mode. To disable the lock, click within the empty Full Edit button. A text box will open,

type the password that was used to set lock mode. press OK.

DPA unit

incorporates a password system and your installer may have set a password to ensure that vital settings

are not altered. In this case you will NOT be able to alter any of the parameters via the PC Editor.

In the PC Editor, select FILE > OPTIONS and then the LOCK tab. This will present you with a menu: