CR-2001 Specifications

Acoustical Operating Principle:

Polar Pattern:

Difference between 0 and 180 :

Frequency Range:

Source Impedance:

Minimum Load Impedance:

Maximum SPL for 0.5% THD at 1K

Hz

:

with -10dB sensitivity reduction:

High Pass Filter:

S/N ratio (DIN 45-590) Ref. level 1 pa:

Maximum Output:

Power Supply (DIN 45596):

Current Consumption:

Weight:

Dimensions:

Shock Mount O-Ring Material:

Pressure Gradient Transducer
Cardioid
≥12dB @ 300Hz-3K

Hz

, ≥15dB @ 1K

Hz

40 Hz - 16 K

Hz

200 ohm ± 20% (1K

Hz

)

1 k ohm
122 dB 25 pa
132 dB 79 pa
6 dB per octave @ 100 Hz
67 dB
300 mV
48 V ± 4 V (Phantom Powering)
2 mA
0.475 kg (17 oz.)
54 mm diameter, 200 mm long
Size #114 Buna-N or Silicone Elastic O-Ring

O

O

These "cardioid" shapes show how distant a sound can be for "equal" volume and are only intended to
illustrate the cardioid pattern. Try talking "around the mic" to relate it to your real world experience.

5

160

160 200

200 250

250 320

320 400

400 500

500 620

620 800

800 1K

1K

1.6

1.6

1.25

1.25

2K

2K

2.5

2.5

3.2

3.2

4K

4K

5K

5K

6.2

6.2

8K

8K

12.5

12.5

10

10

32

32

40

40

50

50

62

62

80

80

100

100 125

125

-1

-1

-2

-2

-3

-3

-4

-4

-5

-5

-6

-6

-7

-7

-8

-8

-9

-9

-10

-10

+1

+1

+1

+1

+1

+1

0

+2

+2

+3

+3

+4

+4

+5

+5

+6

+6

+7

+7

+8

+8

+9

+9

+10

+10

32

32

25

25

20

20

16

16

FROM THESE WHEN NEW

RESPONSE

RESPONSE

AVERAGE CURVE USED TOTEST MICS.
YOUR MIC WILL BE +/- 1.5 dB

CR-2001 ON AXIS (FRONT)
FREQUENCY

FREQUENCY

CR-2001 OFF AXIS (BACK)

CARDIOID PATTERN

SIDE VIEW

SIDE VIEW

TOP VIEW

TOP VIEW

LANGEVINL

A

N

G

E

V

IN