beautypg.com

Specifications – Manley ELOP User Manual

Page 13

background image

SPECIFICATIONS

ALL-TUBE audio path 12AU7WA + 6414 per ch.

Unbalanced 1/4” Inputs And Outputs and...

Balanced Transformer Coupled XLR Inputs And Outputs

Hi-current drive <50 ohm 1/4” & XLR outputs

Silent conductive plastic INPUT attenuators

Max. GAIN REDUCTION 22dB

ATTACK time: 10mS for 6dB GR

RELEASE: 2.5 Seconds for 6dB GR

Maximum Input (Bypass through Line Amplifier) +30 dBv (with Limit “IN” the maximum is entirely variable)

Maximum Output +30 dBv

Headroom (referenced to +4 dBv) 26 dB

Frequency Response: 10 Hz to 70 kHz +/- 0.5 dB

BYPASS switches and AUTOMUTE w/warmup delay

Large ILLUMINATED Sifam VU METERS (older units before serial number MELOP®B716 shipped before 6/2003 use: 26V

1.2W FESTOON LAMPS; Manley’s Part Number: VAR016B) Order spare bulbs using our parts order form. (newest units

after serial number MELOP®B716 shipped after 6/2003 use yellow LED lighting)

Meters switch to read OUTPUT or REDUCTION

STEREO LINK

Side-Chain High-Pass Filter 100Hz or 200Hz

THD & Noise (1kHz @ +4 dBm): .015%

Noise Floor (Gain set to minimum): -80 dB Wideband

Signal to Noise Ratio: 126 dB typical

Maximum gain: 15 dB

Power consumption: 40 watts

Operating mains voltage: Units are purpose built for original destination country’s mains voltage: 100V, 120V, or 220-240VAC

as indicated on the serial number badge. Power transformer must be replaced in order to change mains operating voltage.

120VAC units may NOT be rewired to put the primaries of the power transformer in series for 220-240V operation or a large

radiated field of hum will develop. If changing locations/voltages, the power transformer must be replaced with the dedicated

one for the voltage at which it will operate.

Mains Voltage Frequency: 50~ 60Hz

Dimensions: 19” x 3 1/2” x 10” (occupies 2u)

Shipping weight: 16 lbs.