beautypg.com

Front panel, Manley – Manley STEREO VARIABLE MU LIMITER / COMPRESSOR - 1994 - 3/2004 User Manual

Page 6

background image

MANLEY

LABORATORIES INC.

REDUCTION dB

6

0

2

4

8

10

12

IN

BYPASS

BALANCE

LIMIT

COMPRESS

RECOVERY

SLOW

FAST

THRESHOLD

MIN

MAX

OUTPUT

ATTACK

SLOW

FAST

SEP

LINK

POWER

DUAL INPUT

ADJUST

METER

METER

ADJUST

ATTACK

OUTPUT

THRESHOLD

RECOVERY

COMPRESS

LIMIT

BALANCE

BYPASS

IN

MANLEY

LABORATORIES INC.

REDUCTION dB

6

0

2

4

8

10

12

MANLEY

STEREO "VARIABLE-MU" LIMITER COMPRESSOR

FAST

SLOW

MAX

MIN

FAST

SLOW

FRONT PANEL

A H B C D E F G H I E F C D B H A

6

A

IN / BYPASS

Switched in bypass mode, (down position) all effects of the limiting circuitry are
bypassed and will not affect the audio signal. In the bypass mode , the audio
signal passes from the input directly to the output.

B.

COMP. / LIMIT

Selects compression ( 1.5:1) or limiting (4:1) function. Compression is soft -knee,
Limit is a sharper knee. At greater than 12dB of limiting the ratio increases (up to
20:1 maximum)

C.

RECOVERY

Recovery times can be selected between

a.

VERY SLOW

8 seconds

b.

SLOW

4 seconds

c.

MEDIUM

.6 seconds

d.

FAST

.4 second

e.

VERY FAST

.2 second

D.

THRESHOLD

Continuously variable gain reduction threshold control.
Determines the necessary amplitude for compression or limiting to take effect.
Most extreme effect is at the MIN (fully counter clockwise) position. The lower
the threshold, the more that gets limited.

E.

OUTPUT ATTENUATE

Continuously variable attenuation of output signal leaving the amplifier circuitry.
Full attenuation occurs at the full counterclockwise position.
This control is active only in IN mode.

F.

ATTACK

Continuously variable sensitivity of transient detection. Determines the necessary
length of transient to initiate gain reduction. Fast =25mS, Med =50mS, Slow
=70mS.
Fully counter clockwise at the slowest setting will prevent most percussive
signals from causing limiting or compression.

G.

DUAL INPUT

Continuously variable attenuation of input signal entering the amplifier limiting
circuitry
Full attenuation occurs at the fully counterclockwise position.
This control is active only in IN mode.

I.

LINK

When switched to "SEP" left side is independent from the right side. When
switched to "LINK"
both channels are reduced in gain by the same number of dB. This insures that
the stereo image is unchanged. The METERs remain independent to help set
THRESHOLDs.

I.

POWER ON/OFF

Power is supplied to the unit when switched UP. Meters will illuminate

H.

GR METER

Measures in decibels amount of reduction