INSTALLATION

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND
LOCAL CODES.

Mount the unit directly to the output of a video source. Be sure to allow sufficient room
for the required minimum bend radius of the fiber cable used.

POWER SOURCE

THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY
ONLY.

This unit requires a +12VDC power source for proper operation. Current draw is
approximately 50mA maximum. In the USA and in Canada an American Fibertek PS-12
is supplied with this unit. The negative side of the power input is directly connected to
ground. ANSI/NFPA 70 Class 2 wiring is recommended.


POWER CONNECTION

Power is supplied to the unit via a two wire copper cable. The red wire is connected to
+12 volt dc and the black wire is connected to ground.

FIBER CONNECTION

The fiber optic connection is made via a ST connector located on the side of the unit.

VIDEO INPUT CONNECTION

The video input connection is made via a BNC connector on the side of the unit. The
video input should be directly connected to an appropriate 75

baseband video source