beautypg.com

American Fibertek RR-913D-SL User Manual

Page 4

background image

4

INSTALLATION

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD
CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES.

The unit slides into any open slot in the SR-20D subrack. Use a small screwdriver to push and lock the
two ¼ turn fasteners into place.

POWER SOURCE

Power to the unit is supplied by the subrack. Please refer to the SR-20D and PSR-2 instructions for
further details.


POWER CONNECTION

Power is supplied to the unit via a four finger backplane connector. The RR-913D-SL can be inserted
into the subrack or removed from the subrack with power applied to the backplane.

FIBER CONNECTION

The fiber optic connection is made via a FC/PC connector located on the back of the unit. Be sure to
allow sufficient room for the required minimum bend radius of the fiber cable used.


VIDEO OUTPUT CONNECTION

The video output connection is made via a BNC connector on the back of the unit. The 75

Ω video

output can be looped through typical baseband video inputs of switchers, recorders and other
equipment as required. For proper operation, the output must be terminated with 75

Ω. For optimum