American Fibertek RR-915C-SL User Manual
Page 4
4
DATA INPUT / OUTPUT CONNECTIONS
Data input and output connections are made via the top (DATA 1) terminal block on the back of the
unit. See the drawings below for proper orientation of input and output connections. Please note that
the far right pin on each connection drawing corresponds with the far right pin when looking at the
terminal block from the back of the unit.
TYPICAL SYSTEM DATA CONNECTIONS
The RS422 or RS485 four wire interconnection between the RR-915C-SL and the copper device to
which it is attached is based on industry standard EIA terminology for the transmission of electronic
data signals. Using this terminology, the driver of an electronic signal is labeled TX or Data Out.
Correspondingly, the receiver of an electronic signal is labeled RX or Data In. Following this standard,
the Data Out of the copper device is connected to the Data In of the RR-915C-SL. The plus terminal of
the copper device is connected to the plus terminal of the RR-915C-SL and the minus is connected to
the minus. The reverse flow of data from the RR-915C-SL to the copper device follows the same
pattern. Not all manufactures follow standard EIA terminology. Consult the installation instructions for
your copper device if you are unsure which two wires are the drive (data out) wires and which two wires
are the receive (data in) wires.
CONTACT CLOSURE INPUT / OUTPUT CONNECTIONS
Contact Closure input and output connections are made via the bottom (DATA 2) terminal block on the
back of the unit. See the drawing below for proper orientation of input and output connections. Please
note that the far right pin on the connection drawing corresponds with the far right pin when looking at
the terminal block from the back of the unit.
DATA CONFIGURATION
NOTE: This unit is shipped in the following default configuration.
Channel 1: RS485 (4 wire) data
Channel 2: Contact Closure (dry)
For other configurations of channel 1, please refer to the drawing below for changes to the default
switch settings. These configuration switches are located on the bottom of the unit and can be modified
without opening the unit.