MRR-91600C STATUS INDICATORS

The MRR-91600C receiver provides the following front panel LED status indicators to aid in
installation and troubleshooting:

VLI 1 THROUGH VLI 16

A bi-color LED indicator is provided for the each of the sixteen video outputs of the MRR-
91600C. Video status associated with each of these LED s is summarized below.

Video Presence LED

Video Status

Green

Proper Output Video Present

Red

Output Video Not Detected

SYNC

A bi-color LED indicator is provided to monitor the proper serialization of the electrical video
data stream through the MRR-91600C. A SYNC indicator for videos one through eight is located
above the OLI 1 indicator. A SYNC indicator for videos nine through sixteen is located above
the OLI 2 indicator. Sync status associated with these LED s is summarized below.

Sync LED

Sync Status

Green

Proper Data Stream Serialization Present

Red

Data Stream Serialization Not Detected

OLI 1

A bi-color LED indicator monitors the power of the optical input power signal that is being
received at the MRR-91600C from video channels one through eight of the MRT-91600C. AC
power and optical input power status associated with this LED are summarized below.

Optical Level Indicator

AC Power Status

Optical Status

Green

On

Proper Optical Input Power Present

Red

On

Optical Input Not Detected

Off

Off

Check Power Supply Input

OLI 2

A bi-color LED indicator monitors the power of the optical input signal that is being received at
the MRR-91600C from video channels nine through sixteen of the MRT-91600C. AC power and
optical input status associated with this LED are summarized below.

Optical Level Indicator

AC Power Status

Optical Status

Green

On

Proper Optical Input Power Present

Red

On

Optical Input Not Detected

Off

Off

Check Power Supply Input