American Fibertek RR-93282SL User Manual
Page 12
12
DATA TX
A green LED indicator is provided to monitor the data coming in from the electrical interface,
through the RT-482-1470/1490, and out onto the fiber. The intensity of this indicator will vary
with input data patterns, however in typical applications it will cycle on and off as data is
transmitted. Data transmitted status associated with this LED is summarized below.
DATA TX LED
Data Status
Green
Data Flow Present
Off
Data Flow Not Detected
DATA RX
A green LED indicator is provided to monitor the data coming in from the fiber, through the RT-
482-1470/1490, and out onto the electrical interface. The intensity of this indicator will vary with
input data patterns, however in typical applications it will cycle on and off as data is received.
Data received status associated with this LED is summarized below.
DATA RX LED
Data Status
Green
Data Flow Present
Off
Data Flow Not Detected
OLI
A bi-color LED indicator monitors the power of the optical input signal that is being received at
the RT-482-1470/1490 from the corresponding RR-482-1470/1490. DC power and optical input
status associated with this LED are summarized below.
Optical Level Indicator
DC Power Status
Optical Status
Green
On
Proper Optical Input Power Present
Red
On
Optical Input Not Detected
Off
Off
Check Rack Card Seating