beautypg.com

American Fibertek MTX-486 User Manual

Page 3

background image

3

POWER SOURCE

THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY.

This unit requires a +12VDC power source for proper operation. The DC input is diode protected. In the USA
and in Canada an American Fibertek PS-12D is supplied with this unit. The negative side of the power input is
directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended.

POWER CONNECTION

Power is supplied to the unit via a two pin terminal connector. Follow label on unit for proper orientation of +12
volt dc and ground.


FIBER INPUT / OUTPUT CONNECTION

The fiber optic connection is made via a ST connector located on the right side of the unit.


DATA INPUT / OUTPUT CONNECTION

The data input / output connection is made via a RJ12 connector on the right side of the unit.



DATA CONFIGURATION

The MTX-486 is shipped from the factory in the Panasonic PSD data configuration. This unit is
designed for use with Panasonic PSD data only. All internal switches should remain in the
configuration set at the factory.