DATA INPUT / OUTPUT CONNECTIONS
Data input and output connections are located on the rear panel terminal block. A mating plug
connector is provided.
The figure below identifies the specific connections for the Manchester
and RS232 data connections for the MTX-8423C.
MTX-8423C
The figure below identifies the specific connections for the Manchester and RS232 data
connections for the MRX-8423C.
MRX-8423C
DATA TERMINATION REQUIREMENTS
Manchester Data Signals
The Manchester data input on the MRX-8423C is internally terminated with 120 ohms. It is
recommended to provide a 120 ohm termination at the copper device which is terminating the
MTX-8423C data output signal. If the MTX-8423C data output signal is daisy chained to more
than one device, only the last device in the chain should be terminated.