Ge monogram, Zirs360nxlh, Standard installation anti-tip bracket – GE ZIRS360NXLH User Manual
Page 2: Side view front view, Elec, Side view installed with anti-tip bracket, Front view of cutout with anti-tip bracket
STANDARD INSTALLATION
ANTI-TIP BRACKET
Product Specification Created 3/14
24"
(61.0)
2"
(5.1)
4"
(10.2)
7/16"
(1.1)
Trim overlap
35 1/2"
(90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75 1/2"
(191.8)
From floor
to bottom
of electrical
area
3 1/2"
(8.9)
SIDE VIEW
FRONT VIEW
W
ELEC.
5 1/2"
(14.0)
9"
(22.9)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
ZIRS360NXLH
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
24"
(61.0)
2"
(5.1)
4"
(10.2)
7/16"
(1.1)
Trim overlap
35 1/2"
(90.2)
2 5/16"
(5.9)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75 1/2"
(191.8)
From floor
to bottom
of electrical
area
3 1/2"
(8.9)
SIDE VIEW
FRONT VIEW
W
ELEC.
5 1/2"
(14.0)
9"
(22.9)
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
81 1/2"
(207.0)
ZIRS360NXLH
5"
(12.7)
5"
(12.7)
WATER
3 1/2"
(9.0)
Use two
additional hole
locations at end
of brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
A
GE Monogram
®
36" Built-In All-Refrigerator
ZIRS360NXLH
A Mounting the junction
box in this location will
also allow for front
accessability through
access panel.
B Water supply area.
WARNING:
The refrigerator is top
heavy and must be secured
to prevent the possibility of
tipping forward. Failure to
do so may result in death
or serious injury.
The information below is
for cabinet design only.
When installing the anti-
tip system you must use
the product installation
instructions.
The information below
applies to all installation
constructions:
• A wall bracket, bolts and
toggles will be supplied
with the unit.
• The bolts will be used to
attach bracket to wall in
4 locations. Two of the
locations must penetrate
the center of the wall
studs.
• The toggles are used for
stability in drywall and
when metal studs are
encountered. Lag bolts
are used in wood studs.
• In installation opening,
measure 81 ½” from
floor and draw a
horizontal line.
• Locate and mark the wall
studs on horizontal line.
Verify at least two studs
have their centerlines
within the center 32.5”
of installation opening to
ensure 2 wall studs are
penetrated.
• The bracket will be
centered left to right in
opening with bottom of
bracket on the horizontal
line.
• When unit is placed in
opening, the bracket tabs
will align with openings
in back of the unit. The
unit will be secured to the
bracket using supplied
“L” bolts.
See Installation
Instructions for detailed
instructions.
NOTES
B