beautypg.com

GE GTDL210EDWW User Manual

Gtdl210ed, 0 cu. ft. capacity duradrum, Electric dryer with 150 ft. long venting

background image

Listed by

Underwriters

Laboratories

Dimensions and Installation Information (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

geappliances.com or call GE Answer Center

®

service, 800.626.2000.

GTDL210ED

GE

®

7.0 cu. ft. capacity DuraDrum

electric dryer with 150 ft. long venting

Specification Revised 3/14

370135

Exhaust Options:

3-way via rear, right and bottom.

NEMA Receptacle codes:

3-prong dryer cord/30A/4' long (cat #WX9X2) is for NEMA10-30R receptacle
4-prong dryer cord/30A/4' long (cat #WX9X18) is for NEMA14-30R receptacle
Circuit Requirements:

An individual, properly-grounded branch circuit, protected by a 30-amp circuit breaker or a

time-delay fuse, is required.

Electric Dryer Rating:

240V, 5600W, 24A, 60Hz

208V, 4400W, 22A, 60Hz
Note: Dryer wall outlet must be located within 36" of service cord entry and accessible

when dryer is mounted in position.
Installation Information: For complete information, see installation

instructions packed with your dryer.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a

label on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces

are:

0" either side

3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

• Closet doors must be louvered or otherwise ventilated and must contain a mini-

mum of 60 sq. in. of open area equally distributed. If this closet contains both a

washer and a dryer, doors must contain

a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas

dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local

codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for

gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides

3" rear