beautypg.com

GE GTDL210GDWW User Manual

Gtdl210gd, 0 cu. ft. capacity duradrum, Gas dryer with 150 ft. long venting

background image

Dimensions and Installation Information (in inches)

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

geappliances.com or call GE Answer Center

®

service, 800.626.2000.

370134

Specification Revised 3/14

GTDL210GD

GE

®

7.0 cu. ft. capacity DuraDrum

gas dryer with 150 ft. long venting

Exhaust Options:

2-way via rear and bottom. Dryer is shipped exhausted to the rear. Alternate

exhausting knockouts are supplied.
Gas: An individual properly-grounded branch circuit, with a three-prong grounding-

type receptacle, protected by a 15 or 20 amp circuit breaker or a time-delay fuse

is required.
Gas Dryer Electric Rating: 120V, 60Hz, 6A
Gas (BTU/HR): 22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas

supply requires a conversion kit. Check installation instructions for correct kit and

have a qualified gas technician install a conversion kit. See dryer ducting information

for proper installation.
Note: Dryer wall outlet must be located within 36" of service cord entry and

accessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions

packed with your dryer.

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces

are:

0" either side

3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

• Closet doors must be louvered or otherwise ventilated and must contain a minimum

of 60 sq. in. of open area equally distributed. If this closet contains both a washer and

a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes,

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces

0" both sides

3" rear