GTDS820/825ED

GE

®

7.8 cu. ft. capacity electric dryer with stainless steel drum and steam

Specification Revised 3/14

370175

Power Cord Locations 7.8 cu. ft. dryers

Electric Dryer Rating:

240V

5000W

25A

60Hz

208V

4784W

23A

60Hz

Exhaust Option: 4-way rear, right, left and bottom
Circuit Requirements: An individual, properly-grounded branch

circuit, protected by a 30-amp circuit breaker or a time-delay fuse,

is required.
Note: Dryer wall outlet must be located within 36" of service cord

entry and acessible when dryer is mounted in position.
Installation Information: For complete information, see

installation instructions packed with your dryer.

Dimensions and Installation Information (in inches)

Special Installation Requirements

Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum of

60 sq. in. of open area equally distributed. If this closet contains both a washer and a

dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes,

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.