For complete information, see installation instructions packed with your dryer.
Ducting Materials:

For best performance, this dryer should be vented with 4" diameter all rigid metal

exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-

rigid) ducting can be used (Kit WX08X10077). In special installations, it may be

necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.

A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where rigid

metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4” diameter

can be maintained throughout the entire length of the transition duct. Please see

installation instruction packed with your dryer for complete instructions when using

flexible metal (foil type) ducting.
Exhaust Length Calculation:

1. Determine the number of 90° turns needed for your installation. If you exhaust to the

side or bottom of dryer, add one turn.

2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerated

is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within the

duct length should be treated as a 90° elbow. A turn over 45° should be treated as a

90° elbow.

Dryers

must be exhausted to the outside.

Caution: For personal safety do not terminate exhaust into a chimney, under any

enclosed house floor (crawl space), or into an attic, since the accumulated lint could

create a fire hazard or moisture could cause damage. Never terminate the exhaust

into a common duct or plenum with a kitchen exhaust, since the combination of lint

and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,

bird nesting, etc. The wall cap must also be located at least 12" above the ground or

any other obstruction with the opening pointed down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.

Specification Revised 3/14

370137

GTDP280ED

GE

®

7.0 cu. ft. capacity DuraDrum

electric dryer

Dryer exhausting information—use metal

duct only vertical and horizontal ducting

A

B

2-1/2

4

GE Dryer Vent

A

B

2-1/2

4

GE Dryer Vent

A

Best performance
Maximum length

of 4" dia

rigid

metal duct
Exhaust hood type

Domestic dryer models

Number

of 90°

turns

A

4"

opening

B

2-1/2"

opening

GE Frontload Long Vent 7.0

cu. ft. capacity electric dryer

(GFDL)

0

200 ft.

175 ft.

1

185 ft.

165 ft.

2

175 ft.

155 ft.

3

165 ft.

145 ft.

4

155 ft.

135 ft.

5

145 ft.

125 ft.

All Long Vent 6.0 - 8.0 cu. ft.

capacity electric & gas dryers

(GTDL)

0

150 ft.

125 ft.

1

135 ft.

115 ft.

2

125 ft.

105 ft.

3

115 ft.

95 ft.

4

105 ft.

85 ft.

5

95 ft.

75 ft.

All 6.0 - 8.3 cu. ft. capacity

models electric and gas dryers

(GFDS, GFDR, GFDN, GTDS,

GTDN, GHDN, GHDS, GTDP,

GLDP, GTDX, HTDP, HTDX)

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

4

25 ft.

15 ft.

DCVH480

0

90 ft.

60 ft.

1

60 ft.

45 ft.

2

45 ft.

35 ft.

3

35 ft.

25 ft.

All 3.6 cu. ft. (DSKS, DSKP)

electric dryers

0

46 ft.

37 ft.

1

37 ft.

30 ft.

2

30 ft.

22 ft.

3

23 ft.

15 ft.

Laundry Center GTUP270,

GTUN275

0

56 ft.

42 ft.

1

48 ft.

34 ft.

2

40 ft.

26 ft.

3

32 ft.

18 ft.

Laundry Center GTUP240

0

43 ft.

36 ft.

1

33 ft.

26 ft.

2

24 ft.

16 ft.

For every extra 90° elbow, reduce the allowable vent system length by 10 ft.

Two 45° elbows will be treated like one 90° elbow.

For the side exhaust installations, add one 90° elbow to the chart.

The total vent system length includes all the straight portions and elbows of the system (transition

duct included).

Laundry Center length includes factory-installed elbow that does not impact vent length.