GE GTDX400EDWS User Manual
Gtdx400ed, 0 cu. ft. capacity duradrum, Electric dryer
Listed by
Underwriters
Laboratories
For answers to your Monogram,
®
GE Profile
™
or
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
370239
GTDX400ED
GE
®
6.0 cu. ft. capacity DuraDrum
™
electric dryer
36
25-1/2
42
54-1/2
Side View
27
Rear View
36
42
27
2
5-1/2
2-1/2
25-1/2*
Side View
Rear View
4-3/4
25-3/4
23-1/2
11-3/4
RCA Washer/Dryers LC4 QSart
*24-1/2" from the edge of the side panel to the front.�
25-1/2" from the front edge of endcaps.
5.7 cu. ft. Dryers
2
Back View
Power
Cord Hole
30-1/2
5.8, 6.0 and 7.0 cu. ft. Dryers
5
Back View
Power
Cord Hole
4-1/2
Power Cord Locations
Electric Dryer Rating:
240V
5600W
24A
60Hz
208V
4400W
22A
60Hz
Exhaust Option: 4-way rear, right, left and bottom
Circuit Requirements: An individual, properly-grounded branch circuit, protected by
a 30-amp circuit breaker or a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36" of service cord entry and
acessible when dryer is mounted in position.
Installation Information: For complete information, see installation instructions
packed with your dryer.
Dimensions and Installation Information (in inches)
Specification Revised 3/14
Special Installation Requirements
Alcove or Closet Installation:
• If your dryer is approved for installation in an alcove or closet, it will be stated on a label
on the dryer back.
• The dryer MUST be exhausted to the outside.
• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side; 3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.
• Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer and
a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
• The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.