beautypg.com

GE GTDS855EDMC User Manual

GE Dryers

background image

Listed by

Underwriters

Laboratories

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

geappliances.com or call GE Answer Center

®

service, 800.626.2000.

GTDS850/855ED

GE

®

7.8 cu. ft. capacity electric dryer with stainless steel drum and steam

Specification Revised 3/14

370177

Electric Dryer Rating:

240V

5000W

25A

60Hz

208V

4784W

23A

60Hz

Exhaust Option: 4-way rear, right, left and bottom
Circuit Requirements: An individual, properly-grounded

branch circuit, protected by a 30-amp circuit breaker or a

time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36" of service

cord entry and acessible when dryer is mounted in position.
Installation Information: For complete information, see

installation instructions packed with your dryer.

Dimensions and Installation Information (in inches)

Special Installation Requirements
Alcove or Closet Installation:

• If your dryer is approved for installation in an alcove or closet, it will be stated on a label

on the dryer back.

• The dryer MUST be exhausted to the outside.

• Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:

0" either side; 3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”.

• Closet doors must be louvered or otherwise ventilated and must contain a minimum

of 60 sq. in. of open area equally distributed. If this closet contains both a washer and

a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors.

• The installation must conform with the local codes, or in the absence of local codes,

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

• Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
Dryer Exhausting Information : Use metal duct only, vertical and horizontal ducting.

Power Cord Locations 7.8 cu. ft. dryers

This manual is related to the following products: