Troubleshooting – a/d/s/ PH30.2 User Manual
Page 20
troubleshooting
symptom
possible cause
action to take
no output
low or no remote turn-on
check remote turn-on voltage
input
output at amplifier and correct
as needed
fuse blown
check power wire integrity
and reversed polarity, repair
as needed and replace fuse
power wires not connected
check power wire and ground
connections and repair or
replace as needed
audio input not connected
check input connections and
or no output from source
signal integrity, repair or
replace as needed
speaker wires not connected
check speaker wires and repair
or replace as needed
audio cycles on and off
speakers are blown
check system with known
working speaker and repair or
replace speakers as needed
thermal protection engages
make sure there is proper
when amplifier heatsink
ventilation for amplifier and
temperature exceeds 90° C
improve ventilation as needed
loose or poor audio input
check input connections and
repair or replace as needed
distorted output
amplifier level sensitivity set too
reset gain referring to the
high; exceeding maximum
tuning section of the manual
output capability of amplifier
for detailed instructions
impedance load to amplifier too
check speaker impedance load
low
if below 2 stereo or 4
mono rewire speakers to
achieve a higher impedance
shorted speaker wires
check speaker wire
connections and repair or
replace as needed
speaker not connected to
check speaker wiring and
amplifier properly
repair or replace as needed
refer to the installation section
of this manual for detailed
instructions
internal crossover not set
reset crossovers referring to the
properly for speaker
multi-cross™ crossover
configuration section of this
manual
19