symptom

possible cause

action to take

no output

low or no remote turn-on

check remote turn-on voltage

input

output at amplifier and correct
as needed

fuse blown

check power wire integrity
and reversed polarity, repair
as needed and replace fuse

power wires not connected

check power wire and ground
connections and repair or
replace as needed

audio input not connected

check input connections and

or no output from source

signal integrity, repair or
replace as needed

speaker wires not connected

check speaker wires and repair
or replace as needed

audio cycles on and off

speakers are blown

check system with known
working speaker and repair or
replace speakers as needed

thermal protection engages

make sure there is proper

when amplifier heatsink

ventilation for amplifier and

temperature exceeds 90° C

improve ventilation as needed

loose or poor audio input

check input connections and
repair or replace as needed

distorted output

amplifier level sensitivity set too

reset gain referring to the

high; exceeding maximum

tuning section of the manual

output capability of amplifier

for detailed instructions

impedance load to amplifier too

check speaker impedance load

low

if below 2 stereo or 4
mono rewire speakers to
achieve a higher impedance

shorted speaker wires

check speaker wire
connections and repair or
replace as needed

speaker not connected to

check speaker wiring and

amplifier properly

repair or replace as needed
refer to the installation section
of this manual for detailed
instructions

internal crossover not set

reset crossovers referring to the

properly for speaker

multi-cross™ crossover
configuration section of this
manual