Parameters program description – AB Soft XS 25000 User Manual
Page 6

6
PARAMETERS
PROGRAM DESCRIPTION
Current
(Amperes)
Voltage
(V
olts
)
Desulphation
Soft Start
Bulk
Absorption
Recovers a
sulphated battery
Tests the battery
condition
Bulk charge
Peak charge with
minimal fluid loss
MULTI XS 25000
MODE
Desulphation
Soft Start
Bulk
Absorption
NORMAL
or
RECOND
YES
Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h.
14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.
SUPPLY
XS 25000
MODE
Desulphation
Soft Start
Bulk
Absorption
PRESET YES
Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h.
14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.
MULTI XT 14000
MODE
Desulphation
Soft Start
Bulk
Absorption
NORMAL
or
RECOND
YES
Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h.
28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.
SUPPLY
XT 14000
MODE
Desulphation
Soft Start
Bulk
Absorption
PRESET YES
Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h.
28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.