beautypg.com

Duct condition testing – LG DLEX2501V User Manual

Page 24

background image

Your dryer features FlowSense

, an innovative

sensing system that automatically detects

blockages and restrictions in dryer ductwork.

Keeping ductwork clean of lint build-up and free

of restrictions allows clothes to dry faster and

reduces energy use.
NOTE: When the dryer is fi rst installed, this test

should be performed to alert you to any existing

problems with the exhaust duct in your home.

However, since the test performed during normal

operation provides more accurate information on

the condition of the exhaust duct than does the

installation test, the number of bars displayed

during the two tests may not be the same.

To activate the duct condition test cycle:

NOTE: Dryer heating test must be performed

before proceeding. (Gas dryer only)

Then perform the duct condition test below.

Press and hold the BEEPER ON/OFF and

TEMP.CONTROL buttons at the same time.

While holding these buttons, press POWER

ON/OFF.

The dryer will show lnS in the number display

to indicate that it is in duct condition testing

mode.
Press START/PAUSE. The dryer will run for

approximately 2 minutes to test

for blockages or restrictions to air

fl ow in the ductwork.

DUCT CONDITION TESTING

If no bars are shown in the display,

the ductwork is free from blockages

or restrictions.

If all bars are lit, the dryer ductwork

has a blockage that needs to be

removed immediately.

Correct Venting

1

2

3

Restricted or Blocked Airflow

Avoid long runs or runs with multiple elbows

or bends.

Check for blockages and lint buildup.

Make sure the ductwork is not crushed

or restricted.

IMPORTANT: Do NOT interrupt the test cycle!

24

3828EL3003V_en.indd 24

2009.7.14 3:18:15 PM