Operating and Safety Instructions
9. ADJUSTING THE AIR PRESSURE OF PNEUMATIC CLAMPS (AT OUR MODELS LIBRA-02 M and
LIBRA-02 HM)
9.1. Pull the adjustment button of the conditioner upwards (Fig. 6)
a- Turning the adjustment button in clockwise direction increases the pressure
b- Turning the adjustment button in counter clockwise direction decreases the pressure
9.2 Once you read 6-8 Bar on the manometer, push the adjustment button of the
conditioner down and lock it in that position.
The air supply to the machine has to balance 6-8 Bar (90-120 psi) pressure. Don’t operate
the machine at an air pressure lower than 6 Bar (90 psi).
CAUTION!