beautypg.com

Audiovox PRO9776C User Manual

Page 3

background image

128-8787A

3 of 24

3

Rev

A

-

Added new URL

1

1/1
1

To exit program mode, turn ignition off, or press and release valet switch.

RF Programmable Features Bank 3 Is Remote Start Selectable Features:

Feature Selection

1 Chirp

2 Chirps

3 Chirps

4 Chirps

5 Chirps

6 Chirps

1st Defrost Output

Pulsed

10 Mins

2nd RF Start Chirp

Off

On

On & Car Finder

3rd Run Time

5 Mins

10 Mins

15 Mins

20 Mins

45 Mins

60 Mins

4th Parking Lights

On Steady

Flashing

5th Input Check

Voltage

Tach

DBI Tach

Hybrid

6th Voltage Level

>0.5V B4 Start

< 0.5V B4 Start

7th Ign. 2 Select

Off During Crank

On During Crank Same As Accy.

8th Ign. 3 Select

Off During Crank

On During Crank Same As Accy

SAme As Starter

9th Diagnostics

Off

On

10th Crank Time

0.8 Sec

1.0 Sec

1.5 Sec

2.0 Sec

11th Gas/Diesel

Gas

Diesel 10

Diesel 15

Diesel 20

12th Transponder O/P

While R/S On

During Start

Until Ign. Off

13th Temp Start

Not Available

14th Crank Averaging

Averaging

Preset Time

Note: When averaging, the engine must be started 4 times with the key to be effective.

15th R/S Shock

Shunt Until Clear Shunt R/S Cycle

Shunt From Tx

16th Turbo Select

Off

3 Mins

5 Mins

10 Mins

17th Black/Blue (Aux O/P)

Single Pulse

As Feat #1 Bank 2

18th One or Two Press Start Two Press

One Press

Note : When feature #5 is set for Voltage or Hybrid, the unit must also have feature #14 set for Preset Time or the unit will flash the Pk. Lts. 7 times and not

start.

When using the RF programmer, enter the program mode as follows:

Turn the ignition on.

Press and release valet switch 3 time.

Turn ignition off then on.

Press and hold valet switch for 5 seconds.

Siren chirps 2 times indicating access to RF feature program mode.

To exit program mode, turn ignition off, or press and release valet switch.