Lamp Changing Procedure:
1. Turn the power off the projector by pressing the “ ”

button.

2. Allow the projector to cool down at least 30 minutes.
3. Disconnect the power cord.
4. Use a screwdriver to remove the screw from the cover.

1

5. Push up and remove the cover.

2

6. Remove the 2 screws from the lamp module.

3

7. Pull out the lamp module.

4

To replace the lamp module, reverse the previous steps.

1

2

4

3

Replacing the lamp

The projector will detect the lamp life itself. It will show you a
warning message “Lamp is approaching the end of its useful life in
full power operation. Replacement Suggested!” When you see this
message, changing the lamp as soon as possible.
Make sure the projector has been cooled down for at least 30 minutes
before changing the lamp.

Warning: Lamp
compartment is
hot! Allow it to
cool down before
changing lamp!

N

OTE

Appendices

Warning: To reduce the
risk of personal injury,
do not drop the lamp
module or touch the
lamp bulb. The bulb may
shatter and cause injury
if it is dropped.