beautypg.com

Dominator – Aphex Systems Dominator II 722 User Manual

Page 4

background image

Dominator

II

Models 720, 722

Aphex is proudly American…100% owned, engineered and manufactured in the U.S.A.

Aphex is a registered trademark of Aphex Systems, Ltd.
Aphex is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time
to time to existing products without prior notice. Specifications and appearance may differ from those listed or shown.

11068 Randall Street • Sun Valley, CA 91352 • (818) 767-2929 • FAX (818) 767-2641

NOMINAL OPERATING LEVEL

0dBu (for use with +4 or +8dBu)

-10dBu

(Peak Ceiling RANGE switch)

INPUT
Connector:

3-Pin XLR female (pin 1 ground, pin 2 positive, pin 3 negative)

Type:

Transformerless, servo balanced with passive 4th order RF filter
Chassis grounded per AES standards

Impedance:

19.5 k

Unterminated;

same

600

with rear-panel terminator engaged

same

(terminator lifts in bypass)

Nominal Level:

from 0dBu to +8dBu

from -10dBu to 0dBu

Maximum Level:

+26dBu

+16dBu (+14.8dBV)

CMRR (typical):

> 50dB 20Hz to 10kHz

same

RF Rejection:

> 28dB at 800 kHz; > 60dB above 2 mHz

same

OUTPUT
Connector:

3-Pin XLR male (pin 1 ground, pin 2 positive, pin 3 negative)

Type:

Transformerless, servo balanced, chassis grounded per AES standards

Output Impedance:

65

same

Nominal Level:

from 0dBu to +8dBu

from -10dBu to 0dBu

Maximum Level:

+25dBu PK*

+15dBu PK*

AUDIO (Controls set for unity gain, no limiting and flat response except as otherwise noted)
Frequency Response:

+0.2dB 4.5Hz - 50kHz

same

Dynamic Range:

> 108dB

> 106dB

Hum & Noise (unweighted, 22 Hz - 22 kHz):

< -82dBu

< -90dBu

Crosstalk:

< -60dB up to 10kHz

same

THD (Ref.: 1kHz, no limiting):

< 0.006% (+12dBu in)

< 0.006% (+2dBu in)

SMPTE IMD:

< 0.006% (+12dBu in)

< 0.006% (+2dBu in)

720/722 CONTROL & METERING PARAMETERS (on front panel unless otherwise noted)
INPUT GAIN:

+14/-21 dB typical

same

PROCESS ON/OFF:

ON: Active / OFF: Hardwire Bypass

same

LF EQ Boost/Cut:

± 5 dB

same

HF EQ Boost/Cut:

± 5 dB

same

XOVER 1 Frequency:

100 Hz / 210 Hz

same

XOVER 2 Frequency:

1.7 kHz / 3.4 kHz

same

RELEASE Time:

150 mSec to 7 Sec

same

RCH (Relative Crest Height) DENSITY:

-5 to +5

same

STEREO COUPLING:

ON / OFF

same

PEAK CEILING:

+1 to +25dBu (PK)**

-9 to +15dBu (PK)**

Peak Ceiling is adjusted with the COARSE (2dB steps), FINE (0.2dB steps)
and RANGE (0dB/-10dB) controls

LIMITING Meter:

10 segment meter indicates up to 15dB of gain reduction in the channel
with the greatest amount of limiting

600 OHM INPUT TERMINATION:

Each channel is switchable on rear panel (lifts in bypass)

REMOTE Control Jack:

A four pin RJ11 telephone-style connector on the rear panel provides remote
control capacity of the PROCESS ON/OFF bypass relays and dry “tally”
contact for a remote status indicator

722 CONTROL PARAMETERS (722 only)
EMPHASIZED LIMITING (switches are located on the rear panel with LED function indicators located on the front panel)
DE-EMP (De-emphasis):

ON / OFF

same

PRE-EMP (Pre-emphasis):

ON / OFF

same

TIME CONSTANT (Microseconds):

75mS / 50mS

same

OTHER SPECIFICATIONS
Power Input:

IEC standard receptacle with voltage selector, fuse and filter

Power Requirements:

100, 120, 220, or 240 VAC; 50 or 60 Hz

Power Consumption:

30 watts maximum

Power Fuse:

Slow blowing type- 100/120 VAC: 0.375 A; 220/240 VAC: 0.25A

Net Weight:

6 lbs. (2.72 kg)

Shipping Weight:

9 lbs. (4.08 kg)

Dimensions:

19” W x 1.75” H x 9.63” D (482.6 mm x 44.5 mm x 244.6 mm)

EIA Mounting:

Mounts in standard 19” rack, using 1 RU of vertical space and 8.8”
(223mm) of depth behind front panel (not including power or I/O cables)

* Maximum Output Level is limited by the PEAK CEILING setting. The output stage is capable of +26dBu into 600

.

** dB (PK) = peak value of sine wave.

This manual is related to the following products: