Water Inc LVH1120HC User Manual
Water Inc Water boiler

1044 East Del Amo Blvd • Carson, CA 90746 • 310.885.4400 • 800.322.WATER(9283)
Fax 310.885.4385 • Order Desk Fax 888.928.3746
waterinc.com
EVERHOT®
LVH720HC/LVH1120HC
SUPPLEMENTAL INSTALLATION INSTRUCTIONS
(See red colored numbers on installation instructions
and modify as noted below)
Note: If you have any questions regarding these instructions, call
our Service Department at 800-322-9283 extensions 112 or 115
BEFORE proceeding with the installation.
# 1
Clear is changed to tan santoprene tube
# 2
Parts list has changed as follows:
One Faucet, one EverHot Tank Assembly, one 3/8" x
5/16" Quick-Connect Reducing Union with check
valve, one escutcheon with o-ring, one metal special
washer, one piece santoprene tube with clamp.
# 3
Insert O-ring into groove in escutcheon, and place onto
faucet tubes. Install faucet assembly into mounting
hole.
# 4
Number 4 is changed as follows:
Install metal special washer onto faucet shank. Install
nut onto shank and tighten. Install santoprene tube
onto end of shank at least ½”. Apply clamp to top of
tube and squeeze until tight.
# 5
Before final tightening of the washers as discussed in
#4, be sure you have positioned faucet spout in the
desired direction.