beautypg.com

Error codes – Alliance Laundry Systems NK101 User Manual

Page 18

background image

16

505942

Troubleshooting

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

:30

- Timeout waiting for Biberon

insertion

- Bad firmware in reader

:31

- Hotlisted card inserted into the

reader

- Card hotlisted

After control destroys card, the
error is cleared

:50

- Loyalty purse read error

- Bad card

:56

- Loyalty purse write error

- Bad card

Right-
most
dp lit

All

- Network communication error

- Communication problem

Error ends at good
communication

“Err”

All

- Coin error

- Invalid coin pulse(s)

Error ends after several
seconds

“Alrm”

All

- Breakin alarm error

- Service door or coin vault

switches

Error ends after several
seconds

“OFF”

All

- Breakin alarm shutdown error

- Service door or coin vault

switches

Cycle power to clear error

“E:FL”

Topload
Frontload
WX

- Fill error

- Maximum fill time exceeded Cycle power to clear error

“E:dr”

Topload
WX

- Drain error

- Maximum drain time

exceeded or water sensed at
end of a spin step

Cycle power to clear error

“E:SP”

Frontload
WX

- SPI communications error

- Internal communication

problem

Cycle power to clear error

“E:OP”

Dryer
WX

- Open temperature sensor error

- Bad sensor or wiring

Cycle power to clear error

“E:SH”

Dryer
WX

- Shorted temperature sensor error - Bad sensor or wiring

Cycle power to clear error

“E:dL”

Frontload
WX

- Door lock error

- Unable to lock or unlock the

loading door

Error cleared when door lock
condition is corrected

“E:dO”

Frontload
WX

- Door open error

- Door opened during a

running cycle

Cycle power to clear error

“E:Ub”

Frontload
WX

- Unbalance error

- Unable to balance a load

Error cleared after EOC (FL)
Error cleared after 1 min.
(WX)

“E:dF”

WX

- Motor failure error

- Motor failure

Cycle power to clear error

“E:HT”

WX

- Heater error

- Maximum heat time

exceeded

Cycle power to clear error

“E:Pr”

WX

- Pressure switch sequence error

- Pressure switches out of

sequence

Cycle power to clear error

Error Codes

(continued)

Display Machine

Error Description

Error Cause

Error Condition Exit

This manual is related to the following products: