Error codes – Alliance Laundry Systems NK101 User Manual
Page 18

16
505942
Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
:30
- Timeout waiting for Biberon
insertion
- Bad firmware in reader
:31
- Hotlisted card inserted into the
reader
- Card hotlisted
After control destroys card, the
error is cleared
:50
- Loyalty purse read error
- Bad card
:56
- Loyalty purse write error
- Bad card
Right-
most
dp lit
All
- Network communication error
- Communication problem
Error ends at good
communication
“Err”
All
- Coin error
- Invalid coin pulse(s)
Error ends after several
seconds
“Alrm”
All
- Breakin alarm error
- Service door or coin vault
switches
Error ends after several
seconds
“OFF”
All
- Breakin alarm shutdown error
- Service door or coin vault
switches
Cycle power to clear error
“E:FL”
Topload
Frontload
WX
- Fill error
- Maximum fill time exceeded Cycle power to clear error
“E:dr”
Topload
WX
- Drain error
- Maximum drain time
exceeded or water sensed at
end of a spin step
Cycle power to clear error
“E:SP”
Frontload
WX
- SPI communications error
- Internal communication
problem
Cycle power to clear error
“E:OP”
Dryer
WX
- Open temperature sensor error
- Bad sensor or wiring
Cycle power to clear error
“E:SH”
Dryer
WX
- Shorted temperature sensor error - Bad sensor or wiring
Cycle power to clear error
“E:dL”
Frontload
WX
- Door lock error
- Unable to lock or unlock the
loading door
Error cleared when door lock
condition is corrected
“E:dO”
Frontload
WX
- Door open error
- Door opened during a
running cycle
Cycle power to clear error
“E:Ub”
Frontload
WX
- Unbalance error
- Unable to balance a load
Error cleared after EOC (FL)
Error cleared after 1 min.
(WX)
“E:dF”
WX
- Motor failure error
- Motor failure
Cycle power to clear error
“E:HT”
WX
- Heater error
- Maximum heat time
exceeded
Cycle power to clear error
“E:Pr”
WX
- Pressure switch sequence error
- Pressure switches out of
sequence
Cycle power to clear error
Error Codes
(continued)
Display Machine
Error Description
Error Cause
Error Condition Exit