Bosch HMV5052U User Manual
Page 14

14
* If a rectangular-to-round transition adapter is used, first
make sure the damper hinge of the microwave swings
freely. If necessary, cut the damper to fit, using the tin
snips, in order to allow free movement.
Equivalent lengths of duct pieces are based on actual
tests and reflect requirements for good venting
performance with any vent hood.
Duct Pieces
x
Number used
=
Equivalent Length
Rectangular-to-Round Tran-
sition Adaptor*
5 ft (1.5 m)
x
=
Wall Cap
40 ft (12.2 m)
x
=
90° Elbow
10 ft (3 m)
x
=
45° Elbow
5 ft (1.5 m)
x
=
90° Elbow
25 ft (7.6 m)
x
=
45° Elbow
5 ft (1.5 m)
x
=
Roof Cap
24 ft (7.3 m)
x
=
Straight Duct 6" (152 mm
Round or 3 1/4" x 10"
(82 x 254 mm) Rectangular
1 ft (0.3 m)
x
=
Total Ductwork =
This manual is related to the following products:
- HMV8052U HMVP052U 800 Series 30 Inch Over the Range Microwave Installation Guide Benchmark Series 1.8 cu. ft. Over-the-Range Microwave Installation Instructions Professional Series 30 Inch Over-the-Range Microwave Installation Instructions 300 Series 30 Inch Over-the-Range Microwave Oven Installation Instructions