• Do not subject the mains cable to
force.
• The distance between the unit and
heat sources is at least 1.5 m.
• Use an air switch. The air switch must
have functions for magnetic tripping
and heat tripping to prevent short
circuit and overload. The suitable
capacity is specified in the following
table.
NOTE
• Make sure that the live wire, the
neutral wire and the ground wire
in the mains socket are properly
connected.
• Inadequate or incorrect electrical
connections can cause electric shock
or fire.
Grounding requirements
• The unit is a type I electrical
appliance. Make sure that the unit is
properly grounded.
• The yellow-green wire is the ground
wire that cannot be used for other
purposes. Improper grounding can
cause electric shock.
• The ground resistance must comply
with local regulations.
• The mains supply must have reliable
ground terminal. Do not connect
the ground wire to water pipes, gas
pipes, contamination pipes or other
possible unsafe places.
• Fuses must comply with the
prescribed model and rating printed
on the fuse cover or circuit board.
Air conditioner (Btu)
Air switch capacity
09-12K
16A