Electrolux EWF127410X User Manual
Page 19
11. Close the pump door.
Warning!
When the appliance is in use and depending
on the programme selected there can be hot
water in the pump.
Never remove the pump cover during a wash
cycle, always wait until the appliance has fin-
ished the cycle, and is empty. When refitting
the pump cover, ensure it is securely re-tight-
ened so as to stop leaks and young children
being able to remove it.
Cleaning the water inlet filters
If you notice that the machine is taking longer
to fill, check that the filter in the water inlet
hose is not blocked.
1. Turn off the water tap.
2. Unscrew the water inlet hose.
3. Clean the filter in the hose using a hard
bristle brush.
4. Screw the hose back onto the tap.
5. Unscrew the hose from the machine.
Keep a rug nearby because some water
may flow.
6. Clean the filter in the valve with a stiff
brush or with the piece of cloth.
7. Screw the hose back to the machine and
make sure the connection is tight.
8. Turn on the water tap.
Emergency emptying out
If the water is not discharged, proceed as
follows to empty out the machine:
1. pull out the plug from the power socket;
2. close the water tap;
3. if necessary, wait until the water has
cooled down;
4. open the pump door;
5. place a bowl on the floor and place the
end of the emergency emptying hose into
the bowl. Remove its cap. The water
electrolux 19