beautypg.com

Over-the-range microwave ei30sm35q, Over-the-range microwave – Electrolux EI30SM35QS User Manual

Page 3

background image

High standards of quality at Electrolux Home Products, Inc.

mean we are constantly working to improve our products.

We reserve the right to change specifications or

discontinue models without notice.

electrolux Major appliances, n.a.

usa

10200 David Taylor Drive

Charlotte, NC 28262

1-877-4electrolux (1-877-435-3287)

electroluxappliances.com

canada

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxappliances.ca

EI30SM35Q 02/14

© 2014 Electrolux Home Products, Inc.

* Can NOT be installed

in island or peninsula

cabinet arrangements

Over-the-Range Microwave

EI30SM35Q

29

7

/

8

"

15

1

/

32

"

rear

extrusion

lower

extrusion

Power cord

location

Blower plate allows for vertical

or horizontal ducting

Allow at least 26" clearance

for door depth when open

16

13

/

32

"

Backsplash

12"

min.

13"

max.

2" min.

Rear Wall

16

1

/

2

" min.

30" min.

66" min.

from floor

to top of

microwave

Bottom edge of

cabinet MUST be

30" min. from

cooking surface

Cabinet MUST be

capable of

supporting a total

load of 150 lbs.

30"

min.

Microwave MUST

be mounted to

BOTH a top cabinet

AND a wall*

Locate 120V/60Hz grounded outlet inside upper cabinet

30" Over-the-range Microwave specifications

Product Weight – 64 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.6 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded for safe

operation.)

Amps @ 120 Volts = 15 Amps

Always consult local and national electric codes.

Grounded outlet should be located in cabinet above, with hole in base to

route power cord. Carefully follow top template instructions for power cord

clearance when installing beneath smooth, flat cabinets.

Microwave’s ventilation system is preset to recirculate air inside with no

ducting system required. Exhausting air outside is optional, using either

vertical or horizontal ducting system. (Refer to Ducted Option Specifications

for outside ventilation.)

For safe and proper installation, microwave MUST be mounted to BOTH

a top cabinet AND a wall, and connected to at least one wall stud. Can NOT

be installed in island or peninsula cabinet arrangements.

Cabinet bottom MUST be level to insure proper installation.

Cabinet MUST be capable of supporting a total load of 150 lbs.

Filler blocks recommended for installation when cabinet front hangs below

recessed bottom shelf.

Minimum distance of 30" required from cooking surface to bottom edge

of top cabinet.

Minimum distance of 66" required from floor to top of microwave.

Opening between cabinets MUST be 30" wide and free of obstructions.

For openings up to 36" wide, order optional 36" Filler Kit to fill in gap

between unit and cabinets.

Allow 26" minimum clearance for 90° door swing.

ducted Option specifications

For outside ventilation.

Exhaust duct adapter will be needed for outside ventilation, to mate with

standard 3-1/4" x 10" rectangular duct. If round duct required, rectangular-

to-round transition adapter will be needed with no more than 6" diameter.

For most efficient airflow exhaust, use a straight run or as few elbows

as possible with a maximum duct length of 3-1/4" x 10" rectangular or

6" diameter round duct, not to exceed 120 equivalent feet.

For horizontal installation, be sure to allow enough space between wall

studs to accommodate exhaust.

Refer to installation instructions on web for detailed duct preparation and

converting exhaust vent blower system for exterior exhaust ventilation.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxappliances.com for detailed instructions.

Optional accessories

36" Filler Kit: S – (PN # MWFILKTSS).

Over-the-range MicrOwave

EI30SM35QS